Metal roof how pdf




















Flush - Fascia to Soffit Detail. Flush - Inside Corner Detail. Flush - Outside Corner Detail. Flush Sill Detail. Flush FL R4. Flush ASTM 12 x Inside Corner Detail 2. Joint - Horizontal Detail. Joint - Vertical Detail. Parapet Detail. Side Wall Detail. Soffit Detail 1. Soffit Detail 2. Window Condition. Window Condition Detail.

Inside Corner Detail 1. Composite Wall Panel Spec Sheet. Exposed Fastener Panels. Eave Detail. Gable Detail. Head Wall Detail. Inside Corner - Horizontal Detail. Inside Corner - Vertical Detail. Isometric Valley Detail. Outside Corner - Horizontal Detail. Outside Corner - Vertical Detail. Panel Overlap Detail. Peak Detail. Profile Detail. Sidewall Detail. Sill Alternate Detail. Valley Detail. Vented Ridge Detail. Curb Detail.

Overlap Detail. ASTM Florida Approvals FL - Siding 7. FL R-1 7. ASTM 2. Florida Approvals 2. R ASTM R Spec Sheet. Metal Roofing. Eave Detail 2. Eave Detail 3. Fascia to Soffit Transition 1.

Fascia to Soffit Transition 2. Gravel Stop Head Detail. Gutter Detail 1. Gutter Detail 2. Pitch Break Detail. Rake to Masonry Wall Detail. Rake to Metal Wall Detail. Gutter Detail Headwall Detail. Hip-Ridge Detail. PAC Curb Details with small cricket. Other Details Panel Overlap Detail. Plywood Deck Details Eave Detail 1. Rake Detail. Fascia to Rake Detail.

Hip Ridge Detail. Fascia to Rake Wall Detail. SC UL x SC UL X Texas Dept. UL Listings UL UL UL A. UL Table - Clip Spacing. Pencil Ribs. H-Shield CG. H-Shield HD. H-Shield NB. WIP HT. Snap-Clad Spec Sheet. Fascia to Soffit. Gutter Detail. Eave Detail 4. Fascia to Rake Wall. Inside Corner Outside Corner Fascia Rake Wall Detail. Fascia to Soffit Fascia to Soffit 1.

Fascia to Soffit 2. Eave Detail 1. Tite-Loc Spec Sheet. Gravel Stop Detail. ASTM E ASTM x Tite-Loc Plus Spec Sheet.

Snap-On Standing Seam. Fascia to Soffit Transition. Roof to Fascia Transition. Transverse seam for panel low pitch. Transverse seam for panel steep pitch. Panel Transition. Fascia to Soffit Detail 1. Fascia to Soffit Detail 2. Snap-On Batten Spec Sheet.

Transition Detail. Roof - Metal Panel System. Redi-Roof Standing Seam. UL alternate. Offsets Pencil Ribs. Smooth Offsets. With Offsets. With Offsets Spec Sheet Download.

Field Bend Panel Detail. Panel Lap Detail. Rake Wall. Roof Transition Detail. Valley Detail One Piece. Eave Detail w Gutter 1. Eave Detail w Gutter 2. Eave w Fascia Detail. Headwall Detail w Receiver. Rake Detail w "J" Closure. Rake Detail w "W" Receiver. Rake Wall Detail. Rake Wall w Fascia Detail. Ridge Assembly. Steel Deck Details Eave Detail 1. Inside Corner Dtail. PAC 24 Ga. Steel Plywood Deck. Vent Pipe Detail. PAC 24 ga. Steel over Plywood Deck. ASTM E 0. Continuous Clip.

Intermittent Clip. ASTM E FM x FM 22 GA x FM 24 GA x TDI Product Eval. TDI Product Eval 24 gauge steel. Soffit Panels. PAC Soffit - Solid. Flush Reveal Soffit Spec Sheet. There are numerous panel configurations, thicknesses, coatings and detailing that are available for metal roofs. The most common for a non-residential project is a standing seam system, which, in general, involves a series of flat-surface metal sheets with vertical seams standing seams that allow the individual panels to be field connected to each other.

The configuration of these seams can vary, but the end result should always be a contiguous steel surface that is impervious to water intrusion. In addition, the fastening of these panels at the seams needs to be designed with continuous or individual clips that connect the metal panels to the structure below in a manner that satisfies the structural requirements discussed above.

The attachment of these clips should be performed under the surface of the metal roof and allow for necessary thermal movement of the roof panels. Only a panel system that has been tested in compliance with an ASTM E procedure, and one which can structurally resist the design loads developed using the ASCE 7 wind load production, should be specified.

Since the termination of the roof panels is the main location of roof leaks, they need to be specifically identified during the roof design process. There are two different basic designs, which are hydrokinetic and hydrostatic. Even though a minimum roof slope of between and is suggested by many manufacturers and associations, critical areas such as valleys, curbs and eaves are vulnerable and susceptible to water intrusion. This type of metal roof should only be specified when all of the specific conditions have been considered and allowing water under the steel surface in certain areas can be completely handled by underlayment and, therefore, is acceptable.

The basic principle for the seams, valleys and eaves associated with this type of system is to seal these areas permanently. Use either a sealant between metal members, secured by a weatherseal fastener or crimping the seam to permanently prevent any differential movement between metal surfaces involved. All thru-fasteners should be at non-moving locations and flashing locations where both flashing member components are allowed to move together.

Finally, the introduction of solid zinc or stainless steel fastener heads, powdercoated with paint to match the metal roof surface, plus weatherseal washers, which can be totally encapsulated within a concave washer attached to the fastener head, provides a practically non-visible attachment system.

Most architectural non-residential metal roofing systems will include a factory-applied paint. Use only a system which is comparable to a Kynar system, which will carry a minimum of a year total paint warranty.

With respect to weathertightness warranties, make sure that the duration of the warranty and the total manufacturer liability is identified in the specifications. Also, ensure that manufacturer inspections are required and the final warranty will not then exclude contractor workmanship. Manufacturer warranties should be necessary for a product to be included in a specification, but they should be inspected by the specifier to ensure that they are specific to a particular job and meet the requirements of the specifications.